- We rewind Motors from 10 HP to 1200 HP of all type of manufacturers.
- We rewind Generators from 50 KVA to 2000 KVA of all type of manufacturers.
- We have lifting facility of 5, 10 and 15 ton capacities.
- We have Coil Winding Machine of length 2 meters - width 0.6 meters.
- No-load test facility of motors upto 1200HP.
- No-load test facility of generators (with out engine) upto 750KVA using motor.
- Load test facility of generators (with engine) upto 500KVA.
- We have 6,000 to 7,000 sq. feet of area to handle our service work.
- We have Constructed area of 4,000 sq. feet.
Rewinding
We have the capabilities and technical staff to adequately service, redesign or rewind any type of electrical machine at a very competitive price and quality. Following are few of the key differentiating factors that has led to our success rate as compared to other service providers:
- Break down analysis to find out the root cause for the winding failure.
- Verify if the winding details are appropriate. Otherwise re-design.
- Pay attention to quality of the work right from beginning to end of the winding process.
- On completion of winding, we subject the windings to series of tests that include flash test, megger insulation test, mechanical test, resistance measurement etc.
Windings carried out in our facility follow a well-defined standard procedures as follows:
- Dismantling of existing Winding with paid attention to gather the existing winding details.
- Blow off carbon and copper dust from the winding slots using high compressed air.
- Assess winding core for any core damage. If required do re-staggering of the core.
- Insulate the slots using F or H class insulation materials to with stand higher operating temperatures.
- Coil winding to former size and with appropriate tension using double enamelled copper wire to with stand higher mechanical and electrical stress.
- After completion of winding, stress test each individual coils by applying High Voltage between the earth Vs the coil and between the coil Vs the adjustcent coils using a Flash tester. This will help us to identify if there are any insulation issues even before we proceed to the next steps.
- We also take the resistance reading of each individual coils. This will help us to keep an eye on the count of turns.
- Connection of all the coils followed by a Magnetic polarity testing, which will indicate the poles. This will help us to identify if there are any inappropriate current paths.
- Binding of coils followed by High temperature heating.
- Finally, apply quality apoxy resin for higher rating windings or apply moist/Chemical resistent varinsh.